E
ema
X
“SERIES SIX
ELECTRIC INSTANTANEOUS WATER HEATER
FOR EMERGENCY SAFETY EQUIPMENT
INSTALLATION AND OWNERS MANUAL
REQUIRED MAINTENANCE
WARNING
BEFORE ATTEMPTING INSTALLATION OF THIS UNIT OR MAKING ANY ADJUSTMENTS
TO THE UNIT ALWAYS BE SURE MAIN CIRCUIT BREAKER IS OFF TO PREVENT DANGER
OF SERIOUS ELECTRIC SHOCK.
MODEL :
SERIAL NO :
INSTALLATION DATE :
ELEMENT RESISTANCE: OHMS
SWITCH ON FLOW RATE: GPM
OPERATING TEMPERATURE
MIN: MAX:
Eemax Inc., 353 Christian Street, Oxford, CT 06478
1
INSTALLER/ CONSUMER RESPONSIBILITIES
PLEASE TAKE THE TIME TO READ NOT ONLY THIS MANUAL BUT ALSO THE
WARRANTY CARD ENCLOSED. WARRANTY OF THIS HEATER WILL DEPEND ON PROPER
INSTALLATION, OPERATION, AND REQUIRED MAINTENANCE. THE WARRANTY SHALL BE
VOID IF THE DESIGN ORSTRUCTURE OF THE WATER HEATER HAS BEEN ALTERED IN
ANY WAY WHATSOEVER. THE MANUFACTURER OF THIS WATER HEATER WILL NOT BE
LIABLE FOR ANY DAMAGES BECAUSE OF FAILURE TO COMPLY WITH THE INSTALLATION
AND OPERATING INSTRUCTIONS OUTLINED ON THE FOLLOWING PAGES.
IF YOU REQUIRE ANY HELP OR HAVE ANY QUESTIONS RELATING TO THE
INSTALLATION OR PERFORMANCE OF THIS HEATER, PLEASE CALL OUR TECHNICAL
SERVICE DEPARTMENT TOLL-FREE:
1-800-543-6163
HAVE THE INFORMATION LISTED BELOW BEFORE CALLING.
Page view 0
1 2 3 4 5 6 7 8 9 10

Summary of Contents

Page 1 - “SERIES SIX”

EemaX“SERIES SIX” ELECTRIC INSTANTANEOUS WATER HEATERFOR EMERGENCY SAFETY EQUIPMENTINSTALLATION AND OWNERS MANUAL REQUIRED MAINTENANCEWARNINGBEFORE AT

Page 2

REPLACEMENT PARTS DIAGRAMHEATER CORE ASSEMBLY (PLEASE SPECIFY 480 VOLTS ON ANY ORDERS)FOR ED039 PART# EX3491 35.5 OhmsFOR ED048

Page 3

Model Number Volts(delta)3 wireMax . Output @ 480VAmpsPer phaseED039480T24T 480 39kW 47ED048480T24T 480 48kW 58ED054480T24T 480 54kW 65ED063480T24T 48

Page 4 - MOUNTING THE UNIT

GENERALThe Eemax “Series Six” water heater is specifically designed to take incold or pre-heated water and heat it to temperatures suitable for emerge

Page 5 - PLUMBING HOOK-UP

MOUNTING THE UNIT1) The unit should be mounted as close to the point of use as possible.2) This unit must only be mounted in the vertical position wit

Page 6 - ELECTRICAL HOOK-UP

1) The unit is supplied with NPT fittings., USE THESE; DO NOT USE PIPE DOPE AND DONOT SOLDER PIPE TO THE INLET OR OUTLET.2) Take care to ensure that t

Page 7 - COMMISSIONING YOUR HEATER

ELECTRICAL HOOK-UPWARNINGHAZARD OF ELECTRICAL SHOCK! BEFORE BEGINNING ANY WORK ON THEINSTALLATION, MAKE SURE THE ELECTRICAL SUPPLY TO THE HEATER IS T

Page 8 - TROUBLESHOOTING

COMMISSIONING YOUR HEATERIMPORTANTBefore switching “on” the power at the main circuit breaker panel make sure that the hotwater circuit is free of air

Page 9

TROUBLESHOOTINGSYMPTOM: NO HEAT INDICATOR LIGHT OFF1)ELECTRIC SUPPLY IS OFFTurn on the main circuit breaker.2)NO OR LOW WATER FLOW Ensure that the min

Page 10 - REPLACEMENT PARTS DIAGRAM

REQUIRED MAINTENANCE PROCEDURETo Be Performed by Qualified PersonnelMONTHLY CHECKSM1) Ensure main circuit breaker is on.M2) Open outlet valve(s) to ru